Spectacle Frame Bridge Deformation Tester
Product Introduction
Reference standards: EN1836:2005, ISO12870:2004, GB/T14214:2003, etc.
Test reason: The measurement frame has a certain lens retention ability, ensuring that the frame can be safely worn for 2 years or more, preventing the lens from falling off due to a slight impact, affecting the wearing effect.
Parameters
1. Pneumatic device: 30 Pa
2. Maximum pressure: 5N
3. Electronic display and automatic timing device
4. Size: 30 × 32 × 33 CM (length × width × height)
5. Weight: 16 Kg
Standards
EN1836:2005, ISO12870:2004, GB/T14214:2003, etc.
Instrument installation
1. Test environment: temperature 23 ± 2 ° C, relative humidity 60 ± 2%.
2. Place the instrument on a relatively flat test platform.
3. Power connection: AC220V, 50Hz, 5A.