Used for testing wires & cables with the rated voltage through the different refractory level,detect the fire resistance of the insulation, check insulation whether breakdown and circuit’s integrality.
used for testing wires& cables with the rated voltage through the differently refactory level,detect the fire resistance of the insulation ,
Testing power | AC0-1000V, continuously adjustable, current: AC0.01-0.70A,four circuits independent continuously adjustable |
Ribbon burner | nozzle length is 500mm, width is 15mm, contain the venturi mixer |
Burning gas | propane or other gas |
Testing temperature | 650±40℃ |
Specimen size | length about 400mm |
Temperature sensor | ø 2.0 mm Platiniridium temperature sensor, below the specimen |
Spraying head pressure | During 250-350Kpa, flowing speed: 0.25-0.3L/S.m2 |